IECEx, ATEX & INMETRO Certified Purge and Pressurization System for large Electrical Machines
Features
Global approvals
Purge flow capacity up to 14,000 Nl/min
Stable machine pressure with CLAPS technology
Stainless steel enclosure construction
Temperature range -20°C to +55°C
System variants: D801 - Air inlet/outlet on bottom of enclosure; D827 - Ex d / Explosion-proof junction box
The D808 purge and pressurization system delivers purge flowrates up to 14,000 Nl/min and is ideal for very large sized Ex p electrical machines.
The system comprises the Control Unit (CU) and the Relief Valve (RLV). The Control Unit contains the pneumatic logic to monitor and control air flow, pressure and purge timing, and provides the system outputs. The RLV measures purge flow at the outlet and provides over-pressure protection for the machine.
The D808 incorporates Expo’s Closed Loop Automatic Pressurization System (CLAPS). This allows the system to detect a rise or fall of the enclosure’s internal pressure and adjust the leakage compensation rate accordingly.
Pressure variations are more likely during sudden start-up of large rotating electrical machines but can also be caused by changes in running temperature. This system has been specifically designed to maintain a stable internal pressure within the motor enclosure.
There are system variants to cover alternative air flow configurations & alarm output connections - see Specifications & Downloads for further details.
Air Inlet | Instrument quality air,4.2-8 barg |
Purge flow rate | 7,000、8,000、10,000、12,000、14,000 NI/min |
Leakage compensation capacity | Up to 5,100 NI/min |
Temperature range | -20°C to +55°C |
Purge timer | 1-99min |
Timer power source | IS (Intrinsically Safe) Battery or Electro-Pneumatic Power Supply (EPPS) |
Signal outputs | Function: Power interlock, low pressure alarm, intermediate pressure alarm, purge in progress (optional),high pressure alarm (optional) Connection: Ex e junction box |
Certifications* | IECEx、ATEX、INMETRO、EAC |