Certified solutions for the pressurization of drillers cabins and analyser houses
Features
Meets NFPA Class I Div.2 & ATEX Zone 2 standards
Ventilation capacity up to 4,700 m3/hr
Dual redundant fan option
Roof, wall and in-line mounting options
Expo’s RP-Max-Z room pressurization systems are designed for type Z / Ex pz pressurization in accordance with NFPA496 and ATEX for Class I Div 2 and Zone 2 hazardous areas, making the interior of the room a general-purpose location.
Systems are self-contained units incorporating high flow fan units, filtration, pressure measurement and control.
Depending on the application, RP-Max-Z systems are available for single or two-door rooms, with one or two fans. Incoming air, from a non-hazardous location, is brought via ducting to the unit. Depending on local regulations or project specifications, the air inlet may be equipped with gas detection or a fire damper.
Read more here in our whitepaper:"Global Compliance of Rooms in Hazardous Areas
Air flow capacity Single door room – up to 3,000 m3/hr
Two-door room - up to 4,700 m3/hr
Power supply 1ph 230/240V 50/60Hz
3ph 400/480V 50/60Hz
Operating temperature limits -20°C to +40°C
Materials of construction Polyester powder coated mild (carbon) steel. (316 stainless steel as optional)
System inputs Fan Shut Down e.g. from gas detection
Forced High Flow e.g. to clear gas
System outputs Low pressure alarm
System fault
Audible alarm.
Certifications ATEX, NFPA